Turning on the 2A Beam Rotator
date: May 5, 2008
<!-- @page { size: 8.27in 11.69in; margin: 0.79in } P { margin-bottom: 0.08in } -->
Initial conditions: beam in static (DC) mode at operating current
-
ISAC:OPS
-
Record beam spot at nominal current with 2A2M19
-
Make e-Log entry for beam profile and 2A2M20Halo U,D,L,R signals on XTERM 2A2P page
-
Phone CYC:OPS to request rotator mode
-
CYC:OPS
-
Reduce p+ to 10uA
-
Change 2A2M20 Halo total threshold to 500
-
Change 2AQ15/16 (2A TW30/31) to 220A/250A to get a smaller spot (~4mm FWHM) [the settings will vary somewhat depending on the tune; for one tune-up 200A/220A did the trick]
-
Phone ISAC:OPS
-
-
ISAC:OPS
-
Record beam spot at nominal current with 2A2M19
-
Make e-Log entry for beam profile and spot size
-
Based on look-up table (Marik) decide on rotation amplitude and heater setting for p+ goal and beam spot size
-
Set p+ limit; set heater
-
Phone CYC:OPS to request new p+ limit and rotator on at desired amplitude
-
-
CYC:OPS
-
Turn on rotator at requested amplitude XT page 2AB
-
Turn on position stability routine XT page 2AP
-
If 2A2M20 Halo protect looks within operating limits set threshold to 300
-
Otherwise increase rotation amplitude 0.5mm at a time until sufficient halo signal is reached
-
-
Raise current to previous operating level when in DC mode and modify beam rotation amplitude (if changed)
-
Phone ISAC:OPS
-
-
ISAC:OPS
-
Record 2A2M20Halo U,D,L,R signals, P+ current, rotation amplitude in the e-Log, Q15/16 setting (XT page 2AQ)
-
Halo levels should look within the limits, balanced and similar in magnitude to DC mode values
-
Phone CYC:OPS to request desired operating current
-
-
CYC:OPS
-
Raise current to requested level
-